Take
the wedi base element and note that it has a plastic insert prefabricated
into the upper surface. There is also a metal load distribution
plate on the underside.
|  |
|
Now you can start to install the exclusive wedi Fundo Drain. You
can see how the parts fit together if you click
here. Insert the 'O' ring seal in the groove on the
insert. |
Note that the Main Sealing Collar has a solid
rubber section. Offer this face up to the underside of the Fundo
unit so it locates against the plate that is embedded in the unit
(right).
At the same time, insert the screw-threaded Clamping
Collar from the upper side of the Fundo (see far right).
|
|
| Now
you can tighten the two components together with the aid of the
cap-tool. Ensure that the seal is tight between each part and the
Fundo base.
|
|
Key:
1: Clamping Collar
2: wedi Fundo
3: Main Sealing Collar
|